Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J. optom. (Internet) ; 16(2): 135-142, Abr-Jun 2023. ilus, graf, tab
Artigo em Inglês | IBECS | ID: ibc-218465

RESUMO

Purpose: Evaluate the performance of a photochromic contact lens in various lighting conditions throughout the day, including those indoor and outdoor environments where the photochromic contact lens is in a less active or inactive state. Methods: Data from two clinical trials of a photochromic contact lens were analyzed to evaluate its performance in various light environments. Both studies involved a photochromic test lens (ACUVUE® OASYS with Transitions™ Light Intelligent Technology™) and a similar non-photochromic control lens (ACUVUE® OASYS 2-week with HYDRACLEAR® PLUS). The studies were both multi-visit, multi-site, 2-treatment by 3-period randomized crossover (i.e., Test/Control/Control or Control/Test/Test) dispensing studies, with follow-up visits after each 2-week dispensing period. Results: A total of 250 subjects were dispensed lenses across both studies, of which 237 total subjects completed. In situations where exposure to an activating light source is common (e.g., outdoors), the Test lens was preferred nearly 6:1 over the control lens. In situations where exposure to an activating light source is less common – indoors, driving at night, using digital devices –, the Test lens was still preferred over the control lens by margins of 4:1, nearly 4:1, and over 3:1 respectively. The Test lens was superior with respect to quality of vision, ability to see comfortably, clarity of vision, reduction of squinting while using computers and reduction of bright light while driving at night. Conclusion: The photochromic test contact lens was rated superior to a non-photochromic control lens in environmental situations where the lens is in a less active or inactive state.(AU)


Assuntos
Humanos , Masculino , Feminino , Lentes de Contato , Luz , Visão Ocular , Olho , Testes Visuais , Optometria , Oftalmologia
2.
Polymers (Basel) ; 15(3)2023 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-36771910

RESUMO

With the acceleration in oilfield developments, reservoir advantage channels have been gradually developed. This has led to ineffective circulation in the oilfield injection system and a significant decrease in production. The profile control and displacement technology of low-permeability and heterogeneous reservoirs are in urgent need of updating. In this paper, an intelligent profile control and displacement agent is proposed. The controlled release mechanism and profile control and displacement mechanism is clarified by physical simulation experiments. The profile control agent is a nanocapsule with environmental response and controlled release. The structure of the capsule is a core-shell structure, which is composed of an amphiphilic copolymer AP-g-PNIPAAM and Janus functional particles. The surface chemical stability of the micro/nanocapsule is analyzed by a potentiometric method. The study shows that a temperature at 45 °C causes a potential change in the micro/nanocapsule, indicating that the micro/nanocapsule has a slow release at this temperature. When the temperature is in the range of 40 to 45 °C, the absorbance greatly increases; therefore, it is considered that the capsule wall LCST is about 45 °C. Heating causes the surface contraction of the capsule wall to intensify, the micropores in the capsule wall to increase, the release amount to increase and the release rate per unit time to increase. The release time increases proportionally with the increase in capsule wall thickness. When the release time is the same, an alkaline or acidic environment can improve the release rate of the nanocapsule. The effect of profile control and flooding is evaluated through different differential core models. The research shows that the controlled release micro/nanocapsule has a good environmental response and the internal components can be effectively controlled by adjusting the temperature or pH value. This research has shown that the nanocapsules have good application prospects in low-permeability heterogeneous reservoirs.

3.
J Optom ; 16(2): 135-142, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35953430

RESUMO

PURPOSE: Evaluate the performance of a photochromic contact lens in various lighting conditions throughout the day, including those indoor and outdoor environments where the photochromic contact lens is in a less active or inactive state. METHODS: Data from two clinical trials of a photochromic contact lens were analyzed to evaluate its performance in various light environments. Both studies involved a photochromic test lens (ACUVUE® OASYS with Transitions™ Light Intelligent Technology™) and a similar non-photochromic control lens (ACUVUE® OASYS 2-week with HYDRACLEAR® PLUS). The studies were both multi-visit, multi-site, 2-treatment by 3-period randomized crossover (i.e., Test/Control/Control or Control/Test/Test) dispensing studies, with follow-up visits after each 2-week dispensing period. RESULTS: A total of 250 subjects were dispensed lenses across both studies, of which 237 total subjects completed. In situations where exposure to an activating light source is common (e.g., outdoors), the Test lens was preferred nearly 6:1 over the control lens. In situations where exposure to an activating light source is less common - indoors, driving at night, using digital devices -, the Test lens was still preferred over the control lens by margins of 4:1, nearly 4:1, and over 3:1 respectively. The Test lens was superior with respect to quality of vision, ability to see comfortably, clarity of vision, reduction of squinting while using computers and reduction of bright light while driving at night. CONCLUSION: The photochromic test contact lens was rated superior to a non-photochromic control lens in environmental situations where the lens is in a less active or inactive state.


Assuntos
Condução de Veículo , Lentes de Contato Hidrofílicas , Lentes de Contato , Estrabismo , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Visão Ocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...